Chapter 1 · Basic Electrical Concepts · Topic 1.10 · Free

Fuses and Resistance Measurement: Notes, Formulas and MCQs

How a fuse protects a circuit and how to choose one, Preece’s law, and the instruments used to measure resistance.
Fuse

A short piece of wire that melts and breaks the circuit when the current becomes too large, protecting the wiring and the appliance.

Key facts

  • Connected in series with the circuit, in the live (phase) wire, so that when it blows the appliance is disconnected from the live supply.
  • Rated in amperes. Choose a rating just above the normal current: a 1 kW heater on 250 V takes 1000/250 = 4 A, so use a 5 A fuse.
  • Fuse wire needs a low, predictable melting point and fairly high resistivity. Tin–lead alloy is the classic rewireable fuse wire; cartridge and HRC fuses use copper or silver elements, which melt very predictably. Carbon is not used.
  • How much current a fuse wire carries depends on its material, its diameter and how well it is cooled.
Preece’s law
Current that melts the fuse wireA
Wire diameterm
A thicker fuse wire needs a larger current to melt it, for the same material.
Wheatstone bridge at balance
Ratio armsΩ
Standard (variable) armΩ
Unknown resistanceΩ
At balance the galvanometer current is zero. Example: P = 10 Ω, Q = 100 Ω, S = 50 Ω → R = 50 × 10/100 = 5 Ω.

Which instrument measures what

InstrumentMeasures
Wheatstone bridgeMedium resistance (about 1 Ω to 100 kΩ), accurately
Kelvin double bridgeVery low resistance (below about 1 Ω); removes the error of leads and contacts
Megger (insulation tester)Insulation resistance of cables and machines (megaohms)
Maxwell bridge / Schering bridgeInductance / capacitance
Ohmmeter across an open circuitReads infinity
Exam pointLow R → Kelvin double bridge; medium R → Wheatstone bridge; insulation (very high) R → Megger.
Common mistakeA fuse is never connected in parallel with the load: in parallel it would short the supply and would not stop the current to the load.

Practice MCQs: Fuses and Resistance Measurement

Medium
1. Which bridge is best suited to measuring very low resistances (below about 1 Ω)?
Show answer

Answer: D. Kelvin double bridge When the resistance being measured is very small, the resistance of the connecting leads and contacts causes a large error. The Kelvin double bridge uses separate current and potential connections (four-terminal method), which removes that error. Why not the others: the Wheatstone bridge becomes inaccurate below about 1 Ω because of lead resistance; Schering and Maxwell bridges measure capacitance and inductance. Exam tip: Kelvin double bridge → ammeter shunts, cable conductors, motor windings.

Easy
2. Which bridge is commonly used for accurate measurement of medium resistances (about 1 Ω to 100 kΩ)?
Show answer

Answer: C. Wheatstone bridge The Wheatstone bridge compares the unknown resistance with known resistors. At balance (galvanometer reading zero) the unknown is found from R = S × P/Q. It is accurate for medium values. Why not the others: the Kelvin double bridge is for VERY LOW resistances; the Schering bridge measures capacitance; the Maxwell bridge measures inductance. Exam tip: low R → Kelvin; medium R → Wheatstone; insulation R → Megger.

11 MCQs on this topic in the app

Free with a Google sign-up: every question explained, with progress tracking and a Memory Bank.

Practise this chapter