Control Systems MCQs with Explanations and Theory
This chapter covers the control-system questions that recruitment tests repeat most: open-loop and closed-loop control and the effects of feedback; mechanical, thermal, liquid and pneumatic analogies with electrical systems; Laplace transform pairs and theorems; transfer functions, poles and zeros; block diagrams, sensitivity and signal-flow graphs with Mason’s formula; first- and second-order time response (damping ratio, natural frequency, overshoot, peak and settling time); system type and steady-state error constants; stability and the Routh–Hurwitz criterion; root locus; Bode, polar, Nyquist and Nichols plots with gain and phase margin; P, I, D, lead and lag compensation; and control components such as potentiometers, LVDTs, synchros, servomotors, tachogenerators and amplidynes. Every numerical uses one or two steps.
What you will learn
- Distinguish open-loop and closed-loop control and state what negative feedback does to gain, sensitivity, bandwidth, distortion and stability.
- Use the force–voltage and force–current analogies, and the thermal, liquid-level and pneumatic analogies.
- Use the standard Laplace transform pairs, the shifting rules and the initial- and final-value theorems.
- Write transfer functions, find poles, zeros and DC gain, and reduce block diagrams and signal-flow graphs (Mason’s formula).
- Find ωn, ζ, ωd, peak overshoot, peak time, settling time and time constant from a transfer function or differential equation.
- Find system type, Kp, Kv, Ka and the steady-state error for step, ramp and parabolic inputs.
- Test stability from pole positions and the Routh array, and find the gain range for stability.
- Apply root-locus rules and read Bode, polar and Nyquist plots, gain margin and phase margin.
- Describe P, I, D, PI, PID, lead and lag compensators and common control components.
Topics in this chapter
| # | Topic | Access |
|---|---|---|
| 6.1 | Open-Loop and Closed-Loop Control, and the Effects of Feedback Control-system terms, open-loop and closed-loop systems, error (actuating) signal, regulators and servomechanisms, and what negative and positive feedback do. | Free (below) |
| 6.2 | Mechanical, Thermal, Liquid and Pneumatic Analogies Force–voltage and force–current analogies for translational and rotational systems, and thermal, liquid-level and pneumatic analogies with electrical quantities. | Premium |
| 6.3 | Laplace Transforms and Their Theorems Standard Laplace pairs, shifting and delay rules, derivatives and initial conditions, partial fractions, and the initial- and final-value theorems. | Premium |
| 6.4 | Transfer Functions, Poles, Zeros and Circuit Models Definition of the transfer function, zero initial conditions, poles, zeros, DC gain, impulse response and the transfer functions of RL, RC, RLC and thermometer models. | Premium |
| 6.5 | Block Diagrams, Feedback Formula and Sensitivity Series, parallel and feedback reduction, moving summing and take-off points, closed-loop and error ratios, and the sensitivity of a feedback system. | Premium |
| 6.6 | Signal-Flow Graphs and Mason’s Gain Formula Nodes, branches, source, sink and mixed nodes, paths, forward paths, loops, self-loops and non-touching loops, and Mason’s gain formula. | Premium |
| 6.7 | Time Response: First and Second Order Systems Test signals, first-order time constant, ωn, ζ and ωd, underdamped/critically damped/overdamped responses, overshoot, peak time, settling time, and derivative (rate) feedback. | Premium |
| 6.8 | System Type and Steady-State Error System type (number of integrators), position, velocity and acceleration error constants, and steady-state error for step, ramp and parabolic inputs. | Premium |
| 6.9 | Stability and Pole Locations Absolute, marginal and BIBO stability, pole positions and impulse responses, and quick coefficient tests. | Premium |
| 6.10 | Routh–Hurwitz Criterion Building the Routh array, counting sign changes, the two special cases, and finding the gain range and the frequency of sustained oscillation. | Premium |
| 6.11 | Root Locus What the root locus shows, number of branches, starting and ending points, real-axis segments, asymptotes, centroid and breakaway points. | Premium |
| 6.12 | Frequency Response and Bode Plots Sinusoidal steady state, |G(jω)| and phase, bandwidth, octave and decade, Bode slopes and phases of standard factors, polar plots and minimum-phase systems. | Premium |
| 6.13 | Nyquist Criterion, Gain Margin, Phase Margin and Nichols Chart The critical point −1 + j0, encirclements, gain and phase crossover, gain margin and phase margin, relative stability, and the Nichols chart. | Premium |
| 6.14 | Controllers and Compensation P, I, D, PI, PD and PID control, error-rate and output-rate (tachometer) damping, lead, lag and lag-lead networks. | Premium |
| 6.15 | Control Components, Nonlinearities and Modern Methods Potentiometers, LVDT, synchros, thermocouples, servomotors, stepper motors, tachogenerators, amplidynes, magnetic amplifiers, relays, nonlinearities, state variables and sampled-data systems. | Premium |
Free topic 6.1: Open-Loop and Closed-Loop Control, and the Effects of Feedback
Control-system terms, open-loop and closed-loop systems, error (actuating) signal, regulators and servomechanisms, and what negative and positive feedback do.
An arrangement of parts that commands, directs or regulates another system (the plant) so that its output behaves as wanted. The reference input or command r(t) is the desired value; the controlled output c(t) is what the plant actually produces; a disturbance is an unwanted outside input.
The control action does NOT depend on the output. Example: a toaster or washing machine run on a timer — it does not measure how brown the toast is. Simple, cheap and free of oscillation problems, but inaccurate when disturbances or component values change.
The output is measured, fed back and compared with the reference. The difference, the ERROR or ACTUATING signal e = r − b, drives the controller. Examples: thermostat, speed governor, voltage regulator, position servo, the human body (the eye is a closed-loop system with several feedback paths).
Open loop versus closed loop
| Property | Open loop | Closed loop (negative feedback) |
|---|---|---|
| Control action depends on output | No | Yes |
| Accuracy | Depends on calibration | High |
| Effect of disturbances and parameter changes | Large | Reduced |
| Effect of nonlinearities | More sensitive | Less sensitive |
| Tendency to oscillate / instability | None (if the plant is stable) | Possible if badly designed |
| Cost and complexity | Low | Higher (sensor, comparator) |
Effects of negative feedback
- Overall gain is REDUCED: T = G/(1 + GH).
- Sensitivity to changes in G is reduced by the factor (1 + GH).
- Bandwidth is increased and distortion and noise inside the loop are reduced.
- Effects of disturbances and nonlinearities are reduced; transients usually decay faster.
- Stability can improve or get worse — feedback adds a tendency to oscillate if gain and phase are badly chosen.
A regulator keeps the output at a set point that stays constant for long periods (voltage or speed regulator). A servomechanism makes a mechanical position, velocity or acceleration follow a changing command.
Unity feedback: the feedback signal equals the output (H = 1). The command is the input set from outside, independent of the feedback system.
Solved Control Systems MCQs
10 of the 398 questions in this chapter. Choose an option, then read the explanation.
Show answer
Answer: A. A closed-loop system When the output is measured and used to adjust the control action, there is feedback — a closed-loop system. Why not the others: in an open-loop system the action is independent of the output; a timed (sequence) system is a kind of open-loop system; "manual" is not the defining term.
Show answer
Answer: D. It is free from problems caused by nonlinearities An open-loop system has no feedback to correct errors, so nonlinearities and parameter changes affect it MORE, not less. Saying it is free from nonlinearity problems is wrong. Why not the others: open-loop systems are indeed cheaper and simpler, and their action is decided by the input command alone.
Show answer
Answer: A. A closed-loop system with multivariable feedback The eye adjusts its focus, pupil size and position using several feedback signals (image on the retina, balance organs, muscle sense) at once — a closed-loop system with multivariable feedback. Why not the others: it clearly uses feedback, so it is not open loop; it uses more than one feedback signal.
Show answer
Answer: D. Closed-loop system Feedback can return a delayed correction that overshoots, so a closed-loop system can oscillate or even become unstable if badly designed. Why not the others: an open-loop system (with a stable plant) has no feedback path to cause oscillation.
Show answer
Answer: D. Is independent of the output Open loop means there is no feedback: the controller acts only on the input command and never looks at the output. Why not the others: dependence on the output, the error or the feedback signal all describe a closed-loop system.
Show answer
Answer: C. Open-loop system Negative feedback corrects the error caused by nonlinearities and parameter drift. An open-loop system has no such correction, so it is more sensitive. Why not the others: feedback reduces the effect of nonlinearities, so the two are not equal, and nonlinearities do affect both.
Show answer
Answer: A. Actuating (error) signal The actuating signal is e = r − b. When b = r, e = 0, and the controller stops correcting. Why not the others: the reference and feedback are equal (not zero) at that moment; the output is at its desired value, not zero.
Show answer
Answer: D. Actuating (error) signal e = r − b is the actuating or error signal that drives the controller. Why not the others: the manipulated variable is what the actuator changes; the controlled variable is the output; the command is the input from outside.
Show answer
Answer: A. Command The command (reference input, set point) is chosen from outside the loop. Why not the others: a disturbance is also external but UNWANTED and not a set value; the feedback and error signals are produced inside the loop.
Show answer
Answer: A. A closed-loop system Feedback of the output to adjust the action is the defining feature of a closed-loop system. Why not the others: open-loop and sequential (timed) systems ignore the output; "semi-closed" is not a standard class.
Try the free preview in the app, then unlock the full chapter with OhmPK Premium.
