DC Generators MCQs with Explanations and Theory
This chapter covers the DC generator questions that recruitment tests repeat most: Faraday’s law and the commutator; the parts of the machine and what each does; poles, electrical angles and frequency; lap and wave windings and their parallel paths; the EMF equation E = PΦZN/60A; separately excited, shunt, series and compound excitation; residual magnetism, voltage build-up and critical resistance; open-circuit and external characteristics and voltage regulation; armature reaction, interpoles and compensating windings; copper, iron and mechanical losses and maximum efficiency; parallel operation and load sharing; and special machines such as the amplidyne. Every numerical uses one or two steps.
What you will learn
- Explain how Faraday’s and Lenz’s laws and the commutator give a DC output, and why generator torque opposes rotation.
- Name the parts of a DC machine (yoke, poles, armature, commutator, brushes, interpoles) and the purpose of each.
- Use θe = (P/2)θm, f = PN/120 and pole pitch = slots/P.
- Compare lap and wave windings: parallel paths A = P (mP) and A = 2, brushes, pitches and equalizer rings.
- Apply E = PΦZN/60A, and E ∝ ΦN, to find EMF, speed or flux.
- Distinguish separately excited, shunt, series, long-shunt and short-shunt compound, cumulative and differential generators.
- Explain residual magnetism, voltage build-up, field flashing, the OCC and critical field resistance.
- Use Ia = IL + Ish, V = Eg − IaRa and the regulation formula; read external characteristics.
- Describe armature reaction, commutation, interpoles and compensating windings.
- Classify copper, iron and mechanical losses, and find efficiency and the maximum-efficiency condition.
- State the conditions for parallel operation and find load sharing between two sources.
Topics in this chapter
| # | Topic | Access |
|---|---|---|
| 11.1 | Working Principle: Faraday’s Law, Lenz’s Law and the Commutator How rotation in a magnetic field induces EMF, why each coil’s EMF is alternating, how the commutator gives DC, and why generator torque opposes rotation. | Free (below) |
| 11.2 | Construction: Parts and Their Purpose Yoke, poles, field winding, laminated armature, commutator with mica, risers, brushes, bearings, dummy coils, interpoles and compensating windings. | Premium |
| 11.3 | Poles, Electrical Angles, Frequency and Pole Pitch Electrical and mechanical degrees, the frequency of flux reversal in the armature, and pole pitch in slots and degrees. | Premium |
| 11.4 | Armature Windings: Lap and Wave Parallel paths, multiplex windings, brushes, pitches, progressive and retrogressive windings, equalizer rings and winding design checks. | Premium |
| 11.5 | The EMF Equation Derivation and use of E = PΦZN/60A for lap and wave windings, EMF at a new speed, and flux units. | Premium |
| 11.6 | Types of Excitation: Separately Excited, Shunt, Series and Compound How the field is supplied, long-shunt and short-shunt connections, cumulative and differential compounding, and under-, level- and over-compounding. | Premium |
| 11.7 | Residual Magnetism, Voltage Build-up and Critical Resistance How a self-excited generator builds its voltage, the open-circuit characteristic, critical field resistance and speed, why build-up fails, and field flashing. | Premium |
| 11.8 | Load Characteristics and Voltage Regulation Shunt and series current relations, terminal voltage, the OCC, internal and external characteristics, why voltage droops, regulation, feeder drop and load resistance. | Premium |
| 11.9 | Armature Reaction Cross-magnetising and demagnetising effects, neutral axes, the effect of saturation and brush shift, and ampere-turn calculations. | Premium |
| 11.10 | Commutation, Interpoles and Compensating Windings Current reversal under the brush, reactance voltage and sparking, brush position, interpoles and their polarity, and compensating windings. | Premium |
| 11.11 | Losses in a DC Generator Copper, iron (hysteresis and eddy) and mechanical losses, how each varies with load, speed, flux and lamination thickness, and constant vs variable losses. | Premium |
| 11.12 | Efficiency and Maximum Efficiency Mechanical, electrical and overall efficiency, the efficiency curve, the condition for maximum efficiency, and why maximum power transfer is different. | Premium |
| 11.13 | Parallel Operation and Load Sharing Conditions for paralleling, why shunt generators share load well, load transfer with field rheostats, equalizer bars, load-sharing numericals and motoring. | Premium |
| 11.14 | Polarity, Applications and Special Machines Reversing polarity and rotation, speed under load, uses of each generator type, and cross-field machines such as the amplidyne. | Premium |
Free topic 11.1: Working Principle: Faraday’s Law, Lenz’s Law and the Commutator
How rotation in a magnetic field induces EMF, why each coil’s EMF is alternating, how the commutator gives DC, and why generator torque opposes rotation.
A machine that converts mechanical energy from a rotating shaft into DC electrical energy. It does not create energy: a prime mover (engine, turbine or motor) turns the armature, and the electrical output equals the mechanical input minus the losses. A DC generator and a DC motor have the same construction; only the direction of energy flow differs.
Simple picture: field flux + rotating conductors + commutator = DC at the brushes. The poles give the flux, rotation makes the conductors cut it, Faraday’s law gives the induced EMF, and the commutator connects the rotating coils to fixed terminals with one polarity.
| Number of turns | ||
| Flux linked | Wb |
| Flux density | T | |
| Active length | m | |
| Speed of the conductor | m/s | |
| Angle between motion and field |
EMF of one coil during one cycle (e = Emax sin θ)
| Position | EMF |
|---|---|
| 0° | Zero (moving parallel to the flux) |
| 90° | Positive maximum (cutting flux at right angles) |
| 180° | Zero |
| 270° | Negative maximum |
| 360° (= 0°) | Zero again — one cycle complete |
Positions where the EMF is zero lie on the neutral axis midway between the poles; the brushes of a simple two-pole machine are placed there. The positive half-cycle covers 180°, which in a two-pole machine is half a revolution.
A mechanical rectifier. The EMF inside every armature coil is alternating; the commutator reverses the coil’s connections to the brushes each time the coil EMF reverses, so the brush output has one polarity. One coil gives pulsating DC; many coils and segments give an almost smooth output (less ripple).
Counter-torque: when the armature carries current in the magnetic field, the force on its conductors produces a torque that opposes rotation (Lenz’s law). More electrical load → more armature current → more counter-torque, so the prime mover must supply more torque and power to keep the speed. In a generator the armature current flows in the same direction as the generated EMF; in a motor it flows against the back EMF.
| Power developed in the armature (Eg × Ia) | W | |
| Angular speed | rad/s | |
| Speed | rpm |
Counter-torque (Example 22)
- A generator develops 10 kW in its armature at 1000 rpm.
- ω = 2π × 1000/60 = 104.7 rad/s.
- T = 10 000/104.7 ≈ 95.5 N·m (opposing rotation). The prime mover must give a little more to cover rotational losses.
Solved DC Generators MCQs
10 of the 225 questions in this chapter. Choose an option, then read the explanation.
Show answer
Answer: D. 90° e = Emax sin θ is largest when sin θ = 1, i.e. at 90°, where the coil sides cut the flux at right angles. Why not the others: at 180° the EMF is zero again; 270° is the negative maximum; at 45° it is only 0.707 Emax.
Show answer
Answer: A. At 360°, the same position as 0° The sine wave returns to zero at 360°, which is the starting position again; one full cycle is complete. Why not the others: at 300° and 315° the EMF is still negative (sin is −0.87 and −0.71); 450° is the next positive maximum.
Show answer
Answer: D. Half a revolution A half-cycle is 180 electrical degrees. In a two-pole machine electrical and mechanical degrees are equal, so this is 180° of rotation = half a revolution. Why not the others: a quarter revolution (90°) only reaches the peak; one revolution is a full cycle; two revolutions are two cycles.
Show answer
Answer: D. An alternating component at 1 Hz E ∝ ΦN. With N fixed, E follows Φ, so a flux varying at 1 Hz makes the EMF vary at 1 Hz. Why not the others: a steady output needs steady flux; the output follows the flux shape, not a square wave; the EMF is zero only at zero flux.
Show answer
Answer: C. At the top and bottom, where it moves parallel to the field At the top and bottom the conductor moves horizontally, parallel to the flux, so it cuts no flux: e = Blv sin 0° = 0. Why not the others: at the sides it moves vertically, across the flux, so EMF is maximum; at 45° it is 0.707 of maximum; the EMF varies with position.
Show answer
Answer: C. At the left and right sides of the circle At the sides the conductor moves vertically, at right angles to the horizontal flux, so it cuts flux at the greatest rate: e = Blv sin 90° = Blv. Why not the others: at the top and bottom it moves parallel to the flux (zero EMF); at 45° the EMF is 0.707 Blv; the conductor never passes the centre.
Show answer
Answer: D. At the top and bottom, on the geometrical neutral axis A coil’s EMF is zero when its sides are at the top and bottom (moving parallel to the flux). This is the geometrical neutral axis; brushes placed here commutate coils with no EMF. On load, the magnetic neutral shifts and needs correction. Why not the others: facing the poles the coil EMF is maximum, causing heavy sparking; 45° is still under the poles; position matters.
Show answer
Answer: C. DC generator operation In a generator the armature current produces a counter-torque (Lenz’s law) that the prime mover must overcome. Why not the others: in every motor the electromagnetic torque drives the shaft in its direction of rotation.
Show answer
Answer: A. The armature current flows in the same direction as the generated EMF In a generator the EMF drives the current out of the positive terminal into the load, so Ia is in the direction of Eg and V = Eg − IaRa. Why not the others: current against the EMF is motor action (back EMF, V = Eb + IaRa); delivering power needs both current and EMF.
Show answer
Answer: B. It opposes the rotation Lenz’s law: the armature current produces a torque that opposes the motion causing it, so the prime mover must work against it. Why not the others: an aiding torque is motor action; the torque is about the shaft, not along it; it is zero only with no armature current.