DC Motors MCQs with Explanations and Theory
This chapter covers the DC motor questions that recruitment tests repeat most: the motor principle and construction; back emf and the voltage equation; the emf equation, lap and wave windings; torque, developed power and shaft torque; the speed equation and speed regulation; shunt, series, compound and permanent-magnet motors and their characteristics; starters and starting current; field, armature-voltage, armature-resistance and Ward-Leonard speed control; regenerative, dynamic and plugging braking; losses and efficiency; the brake, Swinburne, Hopkinson, retardation and Field tests; and armature reaction, interpoles and ratings. Every numerical uses one or two steps.
What you will learn
- Explain how a DC motor produces torque, using F = BIl and Fleming’s left-hand rule, and name the parts of the machine.
- Use V = Eb + IaRa and E = PΦZN/(60A) to find back emf, armature current and generated emf for lap and wave windings.
- Find developed power, armature torque and shaft torque, and state the condition for maximum developed power.
- Apply N ∝ Eb/Φ and the speed-regulation formula to speed numericals.
- Compare shunt, series and compound motors by connection, torque and speed characteristics and applications.
- Calculate starting current and starter resistance, and describe three-point and four-point starters.
- Choose a speed-control or braking method and state its speed range and character.
- Classify losses, calculate efficiency and the maximum-efficiency condition, and identify the standard tests of DC machines.
Topics in this chapter
| # | Topic | Access |
|---|---|---|
| 12.1 | DC Motor Principle and Construction How a DC motor turns electrical power into shaft power: force on a current-carrying conductor, Fleming’s left-hand rule and the main parts of the machine. | Free (below) |
| 12.2 | Back EMF and the Voltage Equation Why a running motor generates an emf that opposes the supply, the voltage equation V = Eb + IaRa, and how back emf makes the motor self-regulating. | Premium |
| 12.3 | EMF Equation, Windings and Parallel Paths E = PΦZN/60A, number of conductors, lap, wave, duplex and frog-leg windings, armature resistance of parallel paths, and electrical degrees. | Premium |
| 12.4 | Torque, Developed Power and Shaft Torque T = kΦIa, developed power EbIa, shaft torque from output power, lost torque and the condition for maximum developed power. | Premium |
| 12.5 | Speed Equation and Speed Regulation N ∝ Eb/Φ, how voltage, armature drop and flux change speed, and percentage speed regulation. | Premium |
| 12.6 | Types of DC Motors and Their Connections Separately excited, shunt, series, compound (long and short shunt, cumulative and differential) and permanent-magnet motors; field windings and reversal of rotation. | Premium |
| 12.7 | Characteristics of Shunt, Series and Compound Motors Torque–current and speed–torque curves of each motor type, why a series motor must never run without load, and typical applications. | Premium |
| 12.8 | Starting and Starters Why the starting current is huge, how the starting resistance is calculated, and the three-point and four-point starters. | Premium |
| 12.9 | Speed Control: Field, Armature Voltage and Armature Resistance The three basic speed-control methods, constant-torque and constant-power regions, and the danger of field loss. | Premium |
| 12.10 | Ward-Leonard and Series-Parallel Control Ward-Leonard motor-generator speed control and series-parallel control of traction motors. | Premium |
| 12.11 | Braking of DC Motors Regenerative, dynamic (rheostatic) braking and plugging: how each works and where it is used. | Premium |
| 12.12 | Losses and Efficiency Copper, iron, mechanical and brush losses; constant and variable losses; efficiency, the efficiency curve and the maximum-efficiency condition. | Premium |
| 12.13 | Testing of DC Machines Brake test, Swinburne’s test, Hopkinson’s (back-to-back) test, retardation test and Field’s test. | Premium |
| 12.14 | Armature Reaction, Interpoles, Duty Cycle and Ratings Armature reaction, commutation, interpoles and compensating windings, equivalent duty-cycle rating, insulation class and the high-voltage test. | Premium |
Free topic 12.1: DC Motor Principle and Construction
How a DC motor turns electrical power into shaft power: force on a current-carrying conductor, Fleming’s left-hand rule and the main parts of the machine.
A machine that converts direct-current electrical power into mechanical shaft power. A conductor carrying current inside a magnetic field experiences a force; the forces on many armature conductors add up to a turning effect called electromagnetic torque.
| Flux density | T | |
| Conductor current | A | |
| Active length in the field | m | |
| Angle between conductor and field (90° gives maximum force) |
Force on a conductor
- l = 0.1 m, B = 0.8 T, I = 20 A, θ = 90°.
- F = 0.8 × 20 × 0.1.
Thumb = force (motion), First finger = field (N to S), seCond finger = conventional current. The right-hand rule is used for generators (induced emf).
Main parts
- Stator: yoke (frame), main poles with field windings or permanent magnets.
- Armature (rotor): laminated iron core carrying the armature conductors.
- Commutator: segmented copper ring on the shaft; with the brushes it reverses the current in each coil at the right moment so the torque always acts in one direction.
- Brushes: stationary carbon contacts joining the external DC circuit to the rotating commutator.
- Air gap: small clearance between poles and armature; a small gap means low reluctance, so strong flux with fewer field ampere-turns.
- Interpoles: narrow poles between the main poles that improve commutation under load.
Why it matters: a DC motor and a DC generator are the same machine. Yoke, poles, commutator and windings do not tell you which one it is; the direction of energy flow does. In a motor the electromagnetic torque acts in the direction of rotation; in a generator it opposes the prime mover. Small motors of a few horsepower commonly have 2 poles. A DC generator whose small field input controls a large output (for example an amplidyne) works as a rotating amplifier.
Advantages over AC motors: high starting torque and smooth, wide and easy speed control. Disadvantages: brushes and commutator need maintenance, and the machine is usually costlier — DC motors are not "always cheaper".
Solved DC Motors MCQs
10 of the 154 questions in this chapter. Choose an option, then read the explanation.
Show answer
Answer: C. Lower cost in every case DC motors are chosen for their high starting torque and their smooth, wide and simple speed control. They are usually MORE expensive and need more maintenance because of the commutator and brushes. Why not the others: these three are genuine advantages of DC motors.
Show answer
Answer: B. 1.6 N Given: B = 0.8 T, I = 20 A, l = 0.1 m, θ = 90°. Formula: F = BIl sin θ. Solution: F = 0.8 × 20 × 0.1 × 1 = 1.6 N. Answer: 1.6 N. Why not the others: 0.16 N, 16 N and 160 N are decimal-point slips.
Show answer
Answer: A. To keep the magnetic reluctance low Air has a very high reluctance. A small gap gives strong air-gap flux without needing many field ampere-turns. It must still be large enough for safe mechanical clearance. Why not the others: the gap is not a cooling duct, does not remove vibration and has nothing to do with brush noise.
Show answer
Answer: A. 2 Small DC motors are commonly built with 2 poles; larger machines use 4, 6 or more poles to keep the flux per pole, frame size and commutation manageable. Why not the others: 4, 6 and 8 poles are typical of progressively larger machines.
Show answer
Answer: B. Rotating amplifier A small change in field power produces a large change in output power, so the machine amplifies a control signal using mechanical input power — hence "rotating amplifier" (amplidyne, metadyne). Why not the others: the prime mover is the engine that drives the generator; a rotary converter changes AC to DC; "power pump" is not a machine term.
Show answer
Answer: A. DC motor In a motor the electromagnetic torque drives the shaft, so it acts with the rotation. In a generator the electromagnetic torque opposes the prime mover (the counter torque), which is why mechanical input is needed. Why not the others: the generator torque opposes rotation, so the two machines differ.
Show answer
Answer: B. No, the same machine can do both DC motors and generators have the same parts. Whether a machine is motoring or generating depends on the direction of energy flow (Eb < V for a motor, Eg > V for a generator), not on its construction. Why not the others: none of these features fixes the mode of operation.
Show answer
Answer: D. Fleming’s left-hand rule Fleming’s left-hand rule: thumb = force (motion), first finger = field, second finger = current. It is the motor rule. Why not the others: the right-hand rule gives the direction of induced emf (generators); Lenz’s law gives the direction of induced emf opposing its cause; the grip rule gives the field around a conductor.
Show answer
Answer: B. Keeps the torque in one direction As each armature coil passes from under one pole to the next, the commutator and brushes reverse the current in it, so the force on the conductors under each pole always acts in the same direction and the torque is unidirectional. Why not the others: the field is fed with DC; the commutator does not change resistance or flux.
Show answer
Answer: C. 215 V and 185 V Given: V = 200 V, Ra = 0.5 Ω, Ia = 30 A → IaRa = 15 V. Formula: generator Eg = V + IaRa; motor Eb = V − IaRa. Solution: Eg = 200 + 15 = 215 V; Eb = 200 − 15 = 185 V. Answer: 215 V (generator) and 185 V (motor). Why not the others: the reversed pair swaps the two equations; 230/170 V uses 30 V of drop (forgets the 0.5); 200 V ignores the armature drop. Exam tip: generator emf is MORE than the terminal voltage; motor back emf is LESS.
Try the free preview in the app, then unlock the full chapter with OhmPK Premium.