Circuit Breakers and Switchgear MCQs with Explanations and Theory

Arc Interruption, Air/Oil/SF₆/Vacuum Breakers, Timing and Ratings, TRV, Fuses, Relays, Earthing and Surge Protection

This chapter covers the switchgear and protection questions that recruitment tests repeat most: what a circuit breaker, isolator, contactor, fuse and relay each do; how an arc forms and how it is put out; air-break, oil, air-blast, SF₆ and vacuum breakers; contact materials and contact resistance; the trip sequence and the timing terms (opening, arcing, break, clearing and dead time); breaker ratings, breaking capacity and simple fault-level numericals; recovery voltage, TRV, RRRV and current chopping; fuses and HRC fuses; protective relays (overcurrent, thermal, differential, distance, Buchholz), CTs and plug setting multiplier; neutral earthing and symmetrical components; and overvoltages, surge arresters and travelling waves. Every numerical uses one or two steps.

What you will learn

  • State the job of each switchgear device (breaker, isolator, earthing switch, contactor, fuse, relay) and the safe switching sequence.
  • Explain arc formation, ionization and deionization, and the high-resistance and current-zero methods of arc interruption.
  • Compare air-break, bulk-oil, minimum-oil, air-blast, SF₆ and vacuum circuit breakers by medium, principle and application.
  • Use the timing terms and T = 1/f to find break time, clearing time and cycles.
  • Calculate breaking capacity (√3 V I), making current, rated current and fault level (S/Zpu).
  • Explain recovery voltage, TRV, RRRV and current chopping, and find f₀ = 1/(2π√LC) and V = I√(L/C).
  • Describe fuse terms (fusing factor, pre-arcing and arcing time, HRC, current limiting) and Preece’s law.
  • Identify relay types and protection schemes, and find CT ratio, primary pickup, PSM and apparent impedance.
  • Compare neutral-earthing methods, use I₀ = (Ia + Ib + Ic)/3, and explain surge arresters, surge impedance and reflections.

Topics in this chapter

#TopicAccess
15.1Switchgear and Its Devices
What switchgear is, and the separate jobs of the circuit breaker, isolator, earthing switch, contactor, fuse and relay.
Free (below)
15.2The Arc: Formation and Properties
Why an arc forms when contacts part, where its charge carriers come from, how they are removed, and how an arc behaves electrically.
Premium
15.3Methods of Arc Interruption
The high-resistance method and the current-zero method, magnetic blowout and arc chutes, gas blast, spark suppression, and why DC is harder to break.
Premium
15.4Contacts, Contact Resistance and Busbars
Main and arcing contacts and their materials, contact resistance and heating, insulation resistance, and copper versus aluminium busbars.
Premium
15.5Air-Break, Oil and Air-Blast Breakers
How air-break, bulk-oil, minimum-oil and air-blast breakers put out the arc, their typical voltages, advantages and drawbacks, and insulating-oil properties.
Premium
15.6SF₆ and Vacuum Circuit Breakers
Properties of SF₆ gas, puffer and double-pressure designs, SF₆ drawbacks, and the construction and working of the vacuum interrupter.
Premium
15.7Trip Circuit, Operating Sequence and Timing
How a relay trips a breaker, auxiliary contacts and supervision, and the timing terms: opening, arcing, break, clearing, closing and dead time.
Premium
15.8Breaker Ratings and Fault Calculations
Rated voltage and current, breaking, making and short-time ratings, breaking capacity in MVA, and simple rated-current and fault-level numericals.
Premium
15.9Recovery Voltage, TRV, RRRV and Current Chopping
The voltages that appear across the contacts after current zero, why low power factor makes interruption harder, and the overvoltage caused by current chopping.
Premium
15.10Fuses and HRC Fuses
How a fuse works, fuse terms (fusing factor, pre-arcing and arcing time), element materials, Preece’s law, HRC and current-limiting fuses, and motor and transformer fusing.
Premium
15.11Protective Relays: Qualities and Types
Qualities of a protection system, relay operating principles, time characteristics, thermal relays, pickup and reset, and overcurrent and directional relays.
Premium
15.12Protection Schemes, CTs and Relay Settings
Differential (Merz–Price), pilot-wire and carrier schemes, distance relays, the Buchholz relay, negative-sequence and frequency relays, CT/VT safety and PSM numericals.
Premium
15.13Neutral Earthing, Faults and Symmetrical Components
Why and how the neutral is earthed, ungrounded systems and arcing grounds, earth-fault current, zero- and negative-sequence currents, and current-limiting reactors.
Premium
15.14Overvoltages, Surge Protection and Travelling Waves
Causes of overvoltage, surge arresters, horn gaps and sphere gaps, surge impedance and reflection of travelling waves, surge modifiers, and the safe switching sequence.
Premium

Free topic 15.1: Switchgear and Its Devices

What switchgear is, and the separate jobs of the circuit breaker, isolator, earthing switch, contactor, fuse and relay.

Switchgear

The general name for all apparatus used to switch, control, isolate and protect electrical circuits: circuit breakers, isolators (disconnectors), earthing switches, fuses, contactors, current and voltage transformers, protective relays and their control wiring.

Circuit breaker (CB)

A switching device that can MAKE, CARRY and BREAK both normal load current and abnormal (fault) current within its ratings. It must also withstand the heat and the mechanical forces of fault current until it opens.

Who does what

DeviceJobLimitation
Circuit breakerMakes, carries and breaks load and fault currentMust be rated for the system voltage, current and fault level
Isolator (disconnector)Gives a visible, safe isolation gapOperated off-load; never breaks load or fault current
Earthing switchConnects an isolated circuit to earthInterlocked; closed only on a dead, isolated circuit
ContactorFrequent switching of loads such as motorsNeeds a fuse or breaker for short-circuit protection
FuseMelts and breaks overcurrent automaticallyOne-time device; must be replaced
RelayDetects the fault and closes the trip circuitDoes not break the main current itself

Breakers are named by the medium in which the arc is put out: air (air-break), oil (bulk oil and minimum oil), compressed air (air-blast), SF₆ gas and vacuum. The operating mechanism (spring, pneumatic, hydraulic or electromagnetic) is a separate choice and must not be confused with the medium. Contactors are classified by their mechanism: electromagnetic, pneumatic or electropneumatic.

Voltage classes: low voltage (LV) AC equipment is rated up to 1 kV (1000 V). Typical application examples: air-break breakers at LV; bulk-oil breakers up to about 33 kV; vacuum breakers at 11–33 kV; air-blast and SF₆ breakers at 132, 220 and 400 kV. These are typical examples, not strict limits. Flameproof switchgear is built for explosive atmospheres such as coal mines.

Exam pointRelay DETECTS, breaker INTERRUPTS, isolator ISOLATES (off-load). LV AC = up to 1 kV.
Common mistakeCommon confusion: an isolator is not a breaker. Opening an isolator on load draws a dangerous arc.

Solved Circuit Breakers and Switchgear MCQs

10 of the 292 questions in this chapter. Choose an option, then read the explanation.

Easy
1. What is the main function of a circuit breaker?
Show answer

Answer: C. To make, carry and interrupt load and fault current within its ratings A circuit breaker is the switching device that can close (make), carry and open (break) both normal current and fault current, as long as these are within its ratings. Why not the others: a visible off-load gap is the job of an isolator; measuring current is done by a CT; power-factor correction is done by capacitors.

Easy
2. When its operating condition is satisfied, what does a protective relay do?
Show answer

Answer: D. Closes its contacts to energize the breaker trip coil The relay detects the abnormal quantity and closes the trip circuit; the trip coil then opens the breaker, and the BREAKER interrupts the power current. Why not the others: relay contacts are far too small to break fault current; isolators are never used to clear faults; a relay does not limit current. Exam tip: relay detects, breaker interrupts.

Easy
3. For AC switchgear, low voltage (LV) normally means a rated voltage up to about:
Show answer

Answer: A. 1 kV AC equipment rated up to 1000 V (1 kV) is classed as low voltage; above that it is medium or high voltage. Why not the others: 3.3 kV and 11 kV are medium-voltage distribution levels; 33 kV is sub-transmission.

Medium
4. Contactors are classified by the way their contacts are operated. Which of these is NOT an operating-mechanism type?
Show answer

Answer: B. Vacuum Electromagnetic, pneumatic and electropneumatic describe how the contacts are moved. “Vacuum” describes the medium in which the arc is broken (a vacuum contactor), not the mechanism. Exam tip: medium and mechanism are different classifications.

Easy
5. Which group lists media used to extinguish the arc in switching devices?
Show answer

Answer: C. Air, oil, SF₆ and vacuum Breakers are named by their quenching medium: air (air-break and air-blast), insulating oil, SF₆ gas and vacuum. Why not the others: mica, porcelain, glass and PVC are solid insulators; water, glycerine and paper are not arc-quenching media; copper, silver and tungsten are contact metals.

Medium
6. Which of these is an air-insulated switching device that is NOT meant to interrupt fault current?
Show answer

Answer: C. Air-break isolator An air-break isolator (disconnector) opens an air gap to isolate a circuit, but only off-load; it has no arc-quenching ability for fault current. Why not the others: SF₆, vacuum and air-blast breakers are all designed to interrupt fault current.

Easy
7. Under which condition is an isolator (disconnector) meant to be operated?
Show answer

Answer: B. Off-load, with no or negligible current An isolator has no arc-quenching ability. It is opened only after the breaker has interrupted the current, to provide a safe, visible isolation gap. Why not the others: opening it on load or under fault would draw a dangerous arc; it is never a substitute for a breaker.

Medium
8. What is the main difference between a circuit breaker and a contactor?
Show answer

Answer: D. A breaker can interrupt fault current; a contactor is for frequent load switching A contactor is built for very many load operations (for example starting motors) but cannot break large fault currents, so it needs a fuse or breaker for short-circuit protection. A breaker is rated to break fault current. Why not the others: they reverse the roles or confuse a breaker with an isolator.

Easy
9. Where is flameproof switchgear particularly needed?
Show answer

Answer: C. In explosive atmospheres such as coal mines Flameproof enclosures are designed so that an internal spark or explosion cannot ignite the surrounding gas or dust — essential in mines and some chemical plants. The equipment must be certified for that atmosphere.

Medium
10. In an otherwise similar gas gap, which change tends to reduce impact ionization?
Show answer

Answer: A. Reducing the electric field strength across the gap Impact ionization happens when electrons accelerated by the field gain enough energy to knock electrons out of gas atoms. A weaker field accelerates them less, so fewer collisions ionize. Why not the others: a stronger field and more energetic electrons increase ionization; a hotter gas adds thermal ionization.

Get all 14 topics and 292 explained MCQs

Try the free preview in the app, then unlock the full chapter with OhmPK Premium.